Combustible
Toxic
Oxygen
AGD-4000A
Features
  • Equipped with High-Performance Pump for Rapid Gas Leak Detection
  • Attached Transparent Dust Cover for Enhanced Durability by Blocking Dust and Particles
  • Wall-Mounted Design for Easy Installation
  • Supports 4~20mA Output Signal & RS-485 Modbus Communication
Specifications
Detected GasCombustible (CH₄, H₂, etc.), Toxic (Cl₂, NH₃, H₂S, etc.), O₂
Detection TypeAspirated (Sample-draw)
Detection MethodElectrochemical, Catalytic Combustion, PID, NDIR
Detection Range0 ~ 100% LEL, 0 ~ N PPM, 0 ~ 30 VOL%
Detection Speed< 45 Sec / 90% Scale
Accuracy±3% Full Scale
Suction Flow Rate0 ~ 1000 ml/min
Operation Display4-LED (Power, 2 Stage Alarms, Trouble)
Concentration DisplayLCD Display (4-Digit)
Output Signal4-20mA, RS-485 Modbus (Optional)
Operating Temperature-20 ~ +60℃
Operating Humidity5 ~ 95% RH (Non-Condensing)
Operating Power & ConsumptionDC 24V, 2.5W Max.
MaterialPolycarbonate (PC)
Dimensions & Weight188(W) × 160(H) × 134(D) mm, 1.5 kg (Excluding Suction Tube)
  • ACE Electronics Co., Ltd.
  • Address: 192-26, Geurugogae-ro 221beon-gil, Gwangjeok-myeon, Yangju-si, Gyeonggi-do
  • Phone: +82-31-858-2020 · +82-31-858-2021
  • Fax: +82-31-858-2022
  • Email: contact@acetop119.com

  • Terms of Service
  • Privacy Policy
  • Copyright © 1993-2025 ACE Electronics Co., Ltd. All Rights Reserved.