Detected Gas | Combustible Gas (H₂, CH₄, C₂H₂, C₂H₆, etc.) |
---|
Detection Type | Diffusion Type |
---|
Detection Method | Catalytic Cell |
---|
Measurement Range | 0 ~ 100% LEL |
---|
Detection Speed | Within 30 Seconds, 90% Scale |
---|
Accuracy | ±3% / Full Scale |
---|
Operation Display | 4-LED (Power, 2 Alarms, Trouble) |
---|
Concentration Display | FND Display (4 Digit) |
---|
Output Signal | 4-20mA |
---|
RS-485 Modbus (Optional) |
Cable · Transmission Distance | Power + Signal Cable: 3 Wire (Above CVVSB 0.75sq) / Max. 2,500m |
---|
Wire Conduit | 3/4” PF Standard |
---|
Installation Method | 2” Pole Mounting, Wall Mounting, Duct Mounting |
---|
Operating Temperature | -20℃ ~ +60℃ |
---|
Operating Humidity | 5 ~ 99% RH (Non-Condensing) |
---|
Operating Power | DC 24V |
---|
Relay Contact | Alarm 1, Alarm 2 Contact Ratings 3A@120VAC/24VDC, 1A@250VAC |
---|
Dimensions | 157(W) × 200(H) × 110(D) mm |
---|
Weight | 2.0 kg |
---|
Explosion-Proof Certification | Flame-Proof Type Ex db IIC T6 (KGS Certified) |
---|